Skip to main content

Table 4 Calculated kinetic parameters for the adsorption of Cd2+, Pb2+,  and Cr3+ on to Co-DPA

From: Adsorptive removal of heavy metals from wastewater using Cobalt-diphenylamine (Co-DPA) complex

Kinetic model

Pseudo first order

Pseudo second order

Adsorbate

K1 (min−1)

qexp (mg/g)

qecal (mg/g)

R2

K2 (g mg−1mi−1)

qexp (mg/g)

qecal (mg/g)

R2

Cd2+

0.025

0.01857

0.0051

0.9897

8.16

0.01857

0.02

0.994

Pb2+

0.125

0.018026

0.0294

-0.998

6.99

0.018026

0.02

0.997

Cr3+

0.054

0.018757

0.0176

0.923

3.54

0.018757

0.021

0.995