Skip to main content

Table 1 Recoveries, matrix effects, stability and intra-batch, inter-batch accuracy and precision of the columbianadin (n =6)

From: LC–MS/MS determination and pharmacokinetic study of columbianadin in rat plasma after intravenous administration of pure columbianadin

Compound

Concentration(ng mL −1)

Recovery

Matrix effect

Freeze-thaw cycles

At −20°C for 2 weeks

Autosampler for 24 h

Intra-batch

Inter-batch

  

Mean

RSD

Mean

RSD

Remains

RSD

Remains

RSD

Remains

RSD

Accuracy

RSD

Accuracy

RSD

(%)

(%)

(%)

(%)

(%)

(%)

(%)

(%)

(%)

(%)

(%)

(%)

(%)

(%)

 

20

102

9.86

99.7

11.9

97.3

8.85

110

5.81

97.3

12.3

91.9

4.02

92.9

4.29

1000

85.5

8.71

85.6

5.66

102

11.1

103

5.37

90.0

6.24

104

4.73

106

6.09

10000

81.4

6.19

90.9

9.20

101

7.04

92.6

6.46

99.2

5.62

106

7.2

98.6

7.73