Skip to main content

Table 3 Accuracy and precision data for tylosin and josamycin using the proposed method

From: Simultaneous determination of tylosin and josamycin residues in muscles, liver, eggs and milk by MLC with a monolithic column and time-programmed UV detection: application to baby food and formulae

Analyte

Concentration (μg mL−1)

Intra-daya

Inter-dayb

  

Recovery (mean ± S.D.)

Er (%)

Recovery (mean ± S.D.)

Er (%)

Tylosin

50.0

99.8 ± 0.2

0.1

99.1 ± 0.6

0.4

 

100.0

99.5 ± 0.6

0.4

100.2 ± 0.4

0.2

 

150.0

99.6 ± 0.6

0.3

99.7 ± 0.5

0.3

Josamycin

50.0

100.8 ± 0.3

0.2

100.3 ± 0.3

0.2

 

125.0

99.6 ± 0.5

0.3

100.9 ± 0.4

0.2

 

250.0

99.7 ± 0.5

0.3

99.6 ± 0.6

0.4

  1. N.B. Each result is the average of three separate determinations.
  2. aIntra-day: within the day.
  3. bInter-day: three consecutive days.